Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Creepage distances greater than table 11 minima  Measured distance:  
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: >5.5mm 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: >6.5mm 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: >10mm 
Primary heat sink —accessible 
parts / enclosure: >10mm 
L-N before fuse link: 3.7mm  
T501: P—S: >6.5mm  
T502: P—S: >8.0mm 
Pass 
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
No such parts 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No such parts 
N/A 
 
 
14 COMPONENTS 
Pass 
14.1 Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such components 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved .......................... :
 
N/A 