Read Harman Kardon HS 300 (serv.man2) EMC - CB Certificate online
page 13 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY501, CY502
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: C501, C502, C503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
EC502 metal case
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
EC502 metal case
N/A
Shielded by a barrier to V-0 or metal ..................... : N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer’s name and type .............................. :
manufacturer’s name and type .............................. :
Switching mode transformer
T501: BCK-ER4201
T502: BCK-ER2855
Filter L512, L513:
LCL-ET2812
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Pass
14.3.3.2
Transformers meet the constructional
equirements
equirements
Pass
Click on the first or last page to see other HS 300 (serv.man2) service manuals if exist.