Page 58 of 62                               Report No. SH10011244-001  
 
 
 
 
 
 
IEC 60065
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
16.4b 
Delete “Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods” and insert “Subclause 9.1 of 
SS 236”: 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has a 
carrier C supporting two pulleys A and B arranged 
so that the cord is horizontal between the pulleys. 
The carrier moves backward and forward over a 
distance of 1 m at an approximately constant speed 
of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be as 
given in Table 1. 
Screene cords in accordance with Table 7 shall be 
tested before application of the screen and outer 
sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample shall 
be loaded with the current specified in Table 2. 
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall be 
approximately 230 V a.c. For all other cords having 
three or more cores a three-phase a.c. voltage of 
about 400 V shall be applied to three conductors, 
any additional conductors being connected to the 
neutral. 
During the test no open-circuit in any core or short-
circuit between cores shall occur. 
After the test, any sheath on cords having three or 
more cores shall be removed. The cord, or the laid 
up cores, shall then withstand the voltage test 
specified in Subclause 8.2. or 8.3 as appropriate, 
but with a test voltage not exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and 5, see the CB 
bulletin. 
 Pass 
*In parenthesis: clauses according to IEC60065:1992.
 
 
Page of 64
Display