HS 2X0 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 7

Read Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate online

 
          Page 6 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
The EUT is complied with the 
requirements 
Pass 
8.5 
Class I equipment 
Class II 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
 Pass 
 
Class II: Reinforced or double insulation between 
hazardous live parts and accessible parts 
 Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
T502, T503, R558 Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
CY501, CY502, CY503, 
CY504 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 Void 
(A1) 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) :  
N/A 
 
Reinforced insulation > 0,4 mm (mm) .................... : T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Optocoupler U502, U504, 
U505, U515: 0.40mm min. 
Enclosure (front panel): 1.5mm 
min. 
Separation sheet on internal 
enclosure around power board: 
0.41mm min. 
Pass 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
Inside T502, T503. 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
Page of 70