Read Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate online
Page 5 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
For a PORTABLE SOUND SYSTEM, a warning
that excessive sound pressure from earphones
and headphones can cause hearing loss.
(EN 60065 A11:2008)
that excessive sound pressure from earphones
and headphones can cause hearing loss.
(EN 60065 A11:2008)
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
The statement was provided
in manual.
in manual.
Pass
Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 1µSv/h (0,1mR/h)
(EN60065 A11:2008)
(EN60065 A11:2008)
The EUT does not generate
ionizing radiation
ionizing radiation
N/A
A picture is considered to be intelligible if the
specified conditions are met (EN60065 A11:2008)
specified conditions are met (EN60065 A11:2008)
See above
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1
Pass
Emission limits under fault conditions .................... : Laser Optical Pickup: Class 1M
or Class 1
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such supporting parts
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such components.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools required.
Pass
Click on the first or last page to see other HS 2X0 (serv.man2) service manuals if exist.