Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Annex B
Cont.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely filling
the casing, so that CLEARANCES and CREEPAGE
DISTANCES do not exist, if the component passes the
electric strength test in the accordance with the
ompliance clause below and in addition:- passes the
test and inspection criteria of 13.6 with an electric
strength test of 10.3 using the test voltage of 1.5 kV
multiplied by 1,6 and
- is subject to routine testing for electric strength during
manufacturing, using a test voltage of 1,5 kV (for
performance of the test see N.2.1).It is permitted to
bridge this insulation with a capacitor complying with
IEC 60384-14:1993, subclass Y2. A capacitor
classified Y3 according to IEC 60384-14:1993, may
bridge this insulation under the following conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the
test specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Sweden, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals or
other reliable means, and for equipment which is
intended for connection to the building installation
wiring via an industrial plug and socket -outlet or an
appliance coupler, or both, complying with IEC 60309
or with a comparable national standard.