Page 10 of 56
Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ...........................: 48
h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
N/A
No hazard from softening solder
P
Soldered terminations not used as protective mechanism
N/A
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
(see appended table 11.2)
P