Report No.1018947
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.5
Printed boards
P
13.5.1
Clearances and creepage distances between conductors
on printed circuit boards, one of which may be
conductively connected to the mains, as in fig. 10
on printed circuit boards, one of which may be
conductively connected to the mains, as in fig. 10
P
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains,
clearances and creepage distances as in table 12
not conductively connected to the mains,
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...: Y1: CY1, CY2, CY3, CY4
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...: X2: CX1, CX2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
connected to the mains: tests for X2 ......................:
-
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ........................... :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ........................... :
CX1 P
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
No N/A