HKTS 210SUB (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon HKTS 210SUB (serv.man3) EMC - CB Certificate online

Test report no. 1018989E
Page 11 (13)
7.
HARMONICS, EN 61 000-3-2
7.1 Operating environment
Temperature:
24
C
Relative Humidity:
64 %
7.2 Classification of the EUT
This product is classified as a Class A equipment.
7.3 Test set-up and test procedure
Harmonics of the fundamental current were measured up to 2 kHz using a digital power analyzer.
The test voltage was supplied from an AC source which meets the requirements according to the
standard.
The measurement of harmonic currents was performed in the following way:
-
For each harmonic order, measurement of the 1,5s smoothed r.m.s. harmonic current in
each DFT time window were performed.
-
Calculation of the arithmetic average of the measured values from the DFT time windows
over the entire observation period was performed.
7.4 Measurement uncertainty
The measurement uncertainty is:
± 8,4 %.
Measurement uncertainty is calculated in accordance with EA-4/02:1997.
The measurement uncertainty is given with a confidence of 95%.
The uncertainty of the measured values is within the tolerance specified by the standard.
7.5 Test equipment
Equipment
Manufacturer
Type
Inv. No.
AC Power source
EM test
ACS 500
30601
Power analyzer
EM test
DPA 500
12710
Software
EM test
ISMDPA Version 3.2
AF oscillator
Chung Instruments
555
5211
Page of 13