HKTS 210SUB (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 4

Read Harman Kardon HKTS 210SUB (serv.man3) EMC - CB Certificate online

Test report no. 1018989E
Page 4 (13)
3.
TEST SPECIFICATIONS
3.1 Standards
EN 55 013 (2001), Amendment A1 (2003) and Amendment A2 (2006): Sound and television
broadcast receivers and associated equipment – Radio disturbance characteristics - Limits and
methods of measurement.
EN 61 000-3-2 (2006): Limits for harmonic current emissions (equipment input current
16 A).
EN 61 000-3-3 (2008): Limitation of voltage fluctuations and flicker in low-voltage supply systems
for equipment with rated current
16A.
3.2 Additions, deviations and exclusions from standards and accreditation
No additions, deviations or exclusions have been made from standard.
All tests performed are within the scope of the accreditation.
3.3 Mode of operation during the test
During the test the EUT was operating in the following mode:
A 42 Hz sinus signal was connected to “LINE LEVEL IN R/L”
The amplifier was connected to a resistive load and the output level was set to 1/8 of the nominal
maximum audio output power.
Page of 13