Test report no. 1018989E
Page 6 (13)
5.
MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
IN THE FREQUENCY RANGE 0,15 MHz TO 30 MHz
IN THE FREQUENCY RANGE 0,15 MHz TO 30 MHz
5.1 Operating environment
Temperature:
23
C
Relative Humidity:
50 %
5.2 Test set-up and test procedure
0,4m
AMN
EUT
> 0,8m
The mains terminal disturbance voltage was measured with the equipment under test (EUT) in a
screened room. The EUT was connected to an artificial mains network (AMN) placed on the floor.
The EUT was placed on a non-metallic table 0,8 m above the metallic, grounded floor and 0,4 m
from the reference ground plane (RGP) wall. The distance to other metallic surfaces was at least
0,8 m.
screened room. The EUT was connected to an artificial mains network (AMN) placed on the floor.
The EUT was placed on a non-metallic table 0,8 m above the metallic, grounded floor and 0,4 m
from the reference ground plane (RGP) wall. The distance to other metallic surfaces was at least
0,8 m.
Overview sweeps with peak detector were performed at lines L and N respectively. The picture of
the sweep, included in the test report, shows the highest value irrespective of line.
Amplitude measurements were performed with a quasi-peak detector and, with an average
detector.
the sweep, included in the test report, shows the highest value irrespective of line.
Amplitude measurements were performed with a quasi-peak detector and, with an average
detector.