Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
 
National differences  Sweden 
IEC 60065:2001 
(See also Group Differences)            
                                                                
CB Bulletin 110A / SE  06  I
 
14 
Switches containing mercury such as thermostats, 
relays and level controllers are not allowed. 
 
 
Annex B 
Replace NOTE 1 by 
In the y CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). 
Subclause 4.1.1 (Corrigendum 2): 
Add after the first paragraph: 
NOTE – In Sweden, CLASS I equipment which is 
intended for connection to the building installation via a 
non-industrial plug or a non-industrial appliance 
coupler, or both and in addition is intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to an 
earthed mains socket –outlet. 
The marking text shall be as follows: 
 
”Apparaten skall anslutas till jordat uttag” 
 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there are 
additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text is 
identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation forming 
part of a component, it shall at least consist of either 
- two layers of thin sheet material, each of which shall 
pass the electric strength test below, or 
- one layer having a distance through insulation of at 
least 0.4 mm, which shall pass the electric strength test 
below. 
If this insulation forms part of a semiconductor  component 
(e.g. an optocoupler), there is no distance through insulation 
requirement for the insulation consisting of an insulating 
compound completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do not exist, if 
the component passes the electric strength test in the 
accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 with an electric 
strength test of 10.3 using the test voltage of 1.5 kV multiplied 
by 1,6  and 
- is subject to routine testing for electric strength during 
manufacturing, using a test voltage of 1.5 kV (for performance 
of the test see N.2.1).
 
 N/A 
 