HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 48

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 42 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Annex B 
Cont. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following 
conditions: 
- the insulation requirements are satisfied by having a 
capacitor classified Y3 as defined by IEC 60384-14, 
which in addition to the Y3 testing, is tested with an 
Impulse test of 2.5kV defined in IEC 62151, subclause 
6.2.1; 
- the additional testing shall be performed on all the test 
specimens as described in IEC 60384-14; 
- the Impulse test of 2.5kV is to be performed before 
the Endurance Test in IEC 60384-14 in the sequence 
of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE – In Norway, exclusions are applicable for 
equipment which is intended for connection to the 
building installation 
wiring using screw terminals or other reliable means, 
and for equipment which is intended for connection to 
the building installation wiring via an industrial plug and 
socket –outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 N/A 
 