Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 42 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Annex B
Cont.
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE – In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation
wiring using screw terminals or other reliable means,
and for equipment which is intended for connection to
the building installation wiring via an industrial plug and
14:1993, may bridge this insulation under the following
conditions:
- the insulation requirements are satisfied by having a
capacitor classified Y3 as defined by IEC 60384-14,
which in addition to the Y3 testing, is tested with an
Impulse test of 2.5kV defined in IEC 62151, subclause
6.2.1;
- the additional testing shall be performed on all the test
specimens as described in IEC 60384-14;
- the Impulse test of 2.5kV is to be performed before
the Endurance Test in IEC 60384-14 in the sequence
of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE – In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation
wiring using screw terminals or other reliable means,
and for equipment which is intended for connection to
the building installation wiring via an industrial plug and
socket –outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
complying with IEC 60309 or with a comparable
national standard.
N/A