Page 39 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
National differences Norway
IEC 60065:2001
(See also Group Differences)
CB Bulletin 110A / NO 06 I
13.3.1
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
N/A
15.1.1
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
Justification:
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
N/A