HK 990 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 25

Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online

 
Page 24 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) .............................
Ambient temperature t2 (
o
C) .............................
23 
24 
 
 
— 
— 
 
 
 
 
— 
— 
 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1)
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit 
maxK) 
Insulation class 
T1 prim. winding (stand-by transf.) 
1720 
1920 
29 
70 
Class A 
T4 prim. winding (connected at CN9) 
20.0 
23.0 
37 
70 
Class A 
T2 prim. winding (connected at CN8) 
1.4 
1.6 
36 
70 
Class A 
T3 prim. winding (connected at CN7) 
1.4 
1.6 
36 
70 
Class A 
 
9.1 
Shock Hazard  
 
Under normal operating conditions: > 35Vpk ac / 60V dc 
 
Notes:  Reference Annex D  
 
CLASS I: (single phase) 
 AC 
DC 
 
U1:            -        Vpk 
-          mA rms 
U1:           -           V 
-            mA 
 
 
 
 
U2:            -        Vpk 
-         mA rms 
 
 
 
 
 
 
 
CLASS II: (single phase)  
 
U1:        0.5          Vpk 
-      mA rms 
U1:           -           V 
-          mA 
 
 
 
 
U2:       0.1           Vpk 
0.14  mA rms 
 
 
 
 
 
 
 
 
Page of 64
Display