HK 990 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online

 
Page 26 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.1 times rated voltage .............:  110-120 
— 
 Frequency 
(Hz)……………………………………..: 
60 
— 
 Ambient 
temperature 
(
o
C) .......................................: 21-25 
— 
 
No 
Component 
Fault 
Temp Rise/ 
Component 
Other results 
(include description and test duration) 
1 Output 100%  - 
Un=132V, 
Pout=380W/channel 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
Fan 
Blocked             
(fan near T2) 
Main PCB= 47K 
T2 winding= 83K 
T4 winding= 54K 
Un=132V, In=5.2A 
Test duration=1h 
Apparatus goes to protective mode after 
1h. No high temp, no hazard. 
3 Ventilation 
Covered 
Main 
PCB= 
50K 
T2 winding= 90K 
T4 winding= 62K 
Un=132V, In=5.2A 
Test duration=1h 
Apparatus goes to protective mode after 
1h. No high temp, no hazard. 
4 Speaker 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard.
 
5 D6 
s.c 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
6 C26  s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
7 C71  s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
8 D7 
s.c. 
-- 
Un=132V 
Test duration=20min. 
Apparatus goes to protective mode after 
<1min. No high temp, no hazard. 
Page of 64