Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online
Page 20 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg .................: 23.8kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
Apparatus mass > 25 kg or height > 1 m or supplied
with cart or stand. Topple test.
with cart or stand. Topple test.
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces with an area exceeding 0.1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N/A
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A