- Page 10 of 13 -
Report
No.
132230
14.3.3 Transformer/motor,
constructional
requirements
P
Transformer
Part No.
Part No.
Insulation
between
between
Insulation
Res. M Ohms
Test Volt
V (60 sec.)
Clearances / Creepage distances
Measured
Required
CLT5I002ZE #)
Pr - sec
> 100
3KV (rms)
5.3 / 5.3 mm
4.0 / 5.0 mm
Pr - ic
> 100
3KV (rms)
5.3 / 5.3 mm
4.0 / 5.0 mm
#)
Iron core – Sec. = 1.0 mm, therefore iron core to secondary distance is considered to 0 mm.
-
Components / construction
CLT5I002ZE
CLT5I002ZE
Windings on single bobbin.
The center flange provided between primary and
secondary windings. Satisfactory constructed.
Bobbin thickness: > 0.4mm.
Max. Operating voltage: 343Vp / 242Vrms
The center flange provided between primary and
secondary windings. Satisfactory constructed.
Bobbin thickness: > 0.4mm.
Max. Operating voltage: 343Vp / 242Vrms
P
Transformer
Part No
Part No
Insulation
Between
Thick (mm)
X Number
Material
Dielectric strength
test / 60 sec.
CLT5I002ZE
Pr - sec
0.40 mm min. x 2
0.40 mm min. x 1
0.40 mm min. x 1
PET center flange
66 Nylon bobbin cap.
66 Nylon bobbin cap.
Pass *)
Pr - ic
0.60 mm min. x 1
PET bobbin
Pass *)
Pr - ic
0.60 mm min. x 1
66 Nylon bobbin cap. Pass *)
*) Test voltage: 3000 Vrms.