7.1 
TABLE: temperature rise measurements 
Monitored point: 
dT (K) at 
253V, 50Hz
dT (K) at   
198V, 50Hz
dT (K) at 
253V, 60Hz
dT (K) at     
198V, 60Hz 
Limit dT (K)
 *) 
Sub transformer core 
36.7  
31.3  
35.8  
31.3  
85 
E-capacitor, C112 body 
26.6  
23.6  
26.5  
23.6  
85
°C 
PWB near D109 
27.9  
24.9  
27.6  
25.1  
95 
Ambient 24.0
 o
C 25.7
 o
C 24.9
 o
C 25.5
 o
C - 
 
 
 
 
 
 
 
Winding temperature rise 
measurements 
253V, 
50Hz 
198V, 
50Hz 
253V, 
60Hz 
198V, 
60Hz 
— 
 
Ambient temperature t1 (
o
C) : 
22.0 22.0 22.0  22.0 
— 
 
Ambient temperature t2 (
o
C) : 
24.0 25.7 24.9  25.5 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K) 
*) 
Insulation 
class 
Sub transf. Pri. winding (253V, 50Hz) 
3782 
4435 
42.3 
85 
Sub transf. Pri. winding (198V, 50Hz) 
3782 
4314 
32.4 
85 
Sub transf. Pri. winding (253V, 60Hz) 
3782 
4386 
38.1 
85 
Sub transf. Pri. winding (198V, 60Hz) 
3782 
4294 
31.2 
85 
 
 
 
 
 
 
*) Temperature rise limits for Singapore is 10K less 
 
 