HK 3490 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 16

Read Harman Kardon HK 3490 (serv.man3) EMC - CB Certificate online

 
 
- Page 9 of 13 - 
 
 
 
 Report 
No. 
132230 
 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. :
207V or 253V 
— 
 Ambient 
temperature 
(
o
C)  ...................................... :
23-27
    o
— 
Monitored point: 
Under fault conditions 
specified below
 
dT (K) 
Permitted 
dT (K) 
1. *), D109 (A to C), SC, 4 hr;   
Unit shut down after 5 sec. FI stabilised at 0.022A. 
Sub transformer primary winding heated up to 94.7K and stabilised.   
Dielectric strength test OK. No hazard.   
 
Sub transf. 
94.7 
 
Sub transf.
150 
2. *), C112, SC, 4 hr;   
Unit shut down immediately. FI stabilised at 0.023A. 
Sub transformer primary winding heated up to 99.1K and stabilised.   
Dielectric strength test OK. No hazard. 
 
Sub transf. 
99.1 
 
Sub transf.
150 
 
 
 
*) Tested at 253V 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 