Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online
- Page 6 of 7 -
www.nemko.com
Report No. 65743
13.3 - 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage
Clearance
13.3.2
Creepage dist.
13.4
Comm.
1 2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic Live Neutral 326V
230V
2,0mm
4,0mm 2,5mm
4,0mm
1)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,0mm 5,0mm >
7,0mm 2)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,0mm 5,0mm >
7,0mm 3)
Reinforce Primary
Chassis
326V 230V 4,0mm 6,0mm 5,0mm >
6,0mm 4)
Reinforce Primary
Chassis
326V 230V 4,0mm 6,7mm 5,0mm 6,7mm 5)
Reinforce Primary
Secondary 382V 270V 4,0mm 6,0mm 5,6mm 6,0mm 6)
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment
Comments:
1) Measured on PCB before mains fuse (F601).
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between primary solder pin and metal bottom chassis.
4) Measured between primary solder pin and metal mounting guard for transformer.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between primary solder pin and metal bottom chassis.
4) Measured between primary solder pin and metal mounting guard for transformer.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.