Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online
- Page 3 of 7 -
www.nemko.com
Report No. 65743
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse
fuse
Mains power/temperatures/results
C601 S-c 207 - 10
min.
F601,
F603,
F604
F603,
F604
10,7 A
Output signal off immediately.
Input current stabilised at 0,12A.
F603, F604 opened.
No hazard.
(Repeated test three times with
the same result)
Input current stabilised at 0,12A.
F603, F604 opened.
No hazard.
(Repeated test three times with
the same result)
Q319
S-c
253
C - E
10 min. F601,
F603,
F604
F604
4,18 A
Unit shut down immediately.
Input current stabilised at 0,09A.
Q317, Q319, Q321, Q311, Q315,
R349, R325, R347, R353, R337,
R329 damaged.
No hazard.
Input current stabilised at 0,09A.
Q317, Q319, Q321, Q311, Q315,
R349, R325, R347, R353, R337,
R329 damaged.
No hazard.
Q319
S-c
253
B - C
10 min. F601,
F603,
F604
F604
3,09 A
Unit shut down immediately.
Input current stabilised at 0,25A.
Q323, Q309, Q317, Q319, Q321,
R347, R331, R361, R359, R355,
R349 damaged.
No hazard.
Input current stabilised at 0,25A.
Q323, Q309, Q317, Q319, Q321,
R347, R331, R361, R359, R355,
R349 damaged.
No hazard.
Q321
S-c
253
C - E
10 min. F601,
F603,
F604
F604
-
Unit shut down immediately.
Input current stabilised at 0,21A.
Q319, Q321, Q317, Q313, Q309,
R351, R353, R335, R331
damaged.
No hazard.
Input current stabilised at 0,21A.
Q319, Q321, Q317, Q313, Q309,
R351, R353, R335, R331
damaged.
No hazard.
Q321
S-c
253
B - C
10 min. F601,
F603,
F604
F604
7,00 A
Unit shut down immediately.
Input current stabilised at 0,21A.
Q315, Q311, Q321, Q319, Q317,
R351, R353, R347, R349, R333,
R337 damaged.
No hazard.
Input current stabilised at 0,21A.
Q315, Q311, Q321, Q319, Q317,
R351, R353, R347, R349, R333,
R337 damaged.
No hazard.
C307 S-c 253 - 30
min.
F601,
F603,
F604
F603,
F604
2,60 A
L ch. signal output off immediately.
Input current stabilised at 0,98A.
R307, R351, R353 opened.
No hazard.
Input current stabilised at 0,98A.
R307, R351, R353 opened.
No hazard.
C309 S-c 253 - 40
min.
F601,
F603,
F604
F603,
F604
2,40 A
L ch. signal output off immediately.
Input current stabilised at 0,97A.
R353, R307 opened.
No hazard.
Input current stabilised at 0,97A.
R353, R307 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other HK 3480 (serv.man2) service manuals if exist.