Report No. 65743
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse
fuse
Mains power/temperatures/results
D615
S-c
253
A - C
17 min
-
1,76 A
Sub transformer primary winding
heated up to 117K and thermal
fuse opened after 17 min.
Dielectric strength test OK.
No hazard.
heated up to 117K and thermal
fuse opened after 17 min.
Dielectric strength test OK.
No hazard.
D613
S-c
253
A - C
30 min
-
1,67 A
Normal operating.
Input current stabilised at 1,67A.
No component damaged.
No hazard.
Input current stabilised at 1,67A.
No component damaged.
No hazard.
C625
S-c
253
-
19 min
-
0,05 A
Unit shut down immediately.
Sub transformer primary winding
heated up to 118K and thermal fuse
opened after 19 min.
Dielectric strength test OK.
No hazard.
Sub transformer primary winding
heated up to 118K and thermal fuse
opened after 19 min.
Dielectric strength test OK.
No hazard.
C626
S-c
253
-
2 hr
-
0,02 A
Unit shut down immediately.
Sub transformer primary winding
heated up to 73K and stabilised.
Dielectric strength test OK.
No hazard.
Sub transformer primary winding
heated up to 73K and stabilised.
Dielectric strength test OK.
No hazard.
D606
S-c
253
A - C
30 min
F601
1,67 A
Normal operating.
Input current stabilised at 1,67A.
No component damaged.
No hazard.
Input current stabilised at 1,67A.
No component damaged.
No hazard.
C622
S-c
253
-
30 min
F601
1,69 A
Normal operating.
Input current stabilised at 1,69A.
No component damaged.
No hazard.
Input current stabilised at 1,69A.
No component damaged.
No hazard.
SPK 1
terminal
terminal
S-c
253
L - G
10 min
F601,
F603,
F604
F603,
F604
6,20 A
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Cover
opening
opening
Blocked 253
-
18
min. F601,
F603,
F604
F604
1,67 A
The components are heated up to:
- Main transf. pr. Winding : 74K
- Sub transf. pr. winding
- Main transf. pr. Winding : 74K
- Sub transf. pr. winding
: 45K
- PWB near D601
: 60K
- PWB near Q319
: 73K
- Main heat-sink
: 83K
and protection circuit operated.
Input current stabilised at 0,01A.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,01A.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection