- Page 10 of 32 -
www.nemko.com
Report No. 65743
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages >1000 V ac or
>1500 V dc
>1500 V dc
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
Discharge not exceeding 45 µC
No part or contact of a
terminal with stored voltages
between 60V - 15kV
terminal with stored voltages
between 60V - 15kV
N
Energy of discharge not exceeding 350 mJ
No part or contact of a
terminal with stored voltages
exceeding 15kV
terminal with stored voltages
exceeding 15kV
N
9.1.1.2
Test with test finger and test probe
No access to hazardous live
parts
parts
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No live shafts, handles or
levers
levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous live
parts
parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
Measured voltage after 2 sec:
Max. 1 V (peak).
Max. 1 V (peak).
P
If C is not greater than 0,1 µF no test needed
N
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger results in
no hazard.
no hazard.
P
Test hook of fig. 4 for 10 s (20 N)
Test with test hook results in
no hazard.
no hazard.
P
30 mm diameter test tool for 5 s (100 or 250 N) .... :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N
TRF No: IEC/EN 60065F