Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online
- Page 9 of 32 -
www.nemko.com
Report No. 65743
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires are connected
with multi-contact-housing.
with multi-contact-housing.
P
Vibration
test carried out ........................................ :
See 12.1.2
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No internal wiring for mains
socket-outlets but
protective fuse (T2.5A/250V)
provided
socket-outlets but
protective fuse (T2.5A/250V)
provided
P
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such components
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
No all-pole switch
N
8.19.2
Mains switch ON indication
Indicator lamp or FL display
lit-on
lit-on
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
Yes, relay across the capacitors
is Certified component.
See appended table, list of
critical components.
is Certified component.
See appended table, list of
critical components.
P
TRF No: IEC/EN 60065F