Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online
- Page 7 of 32 -
www.nemko.com
Report No. 65743
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No temperatures measured
during heating test and fault
condition tests require this test
(7.2) to be performed.
during heating test and fault
condition tests require this test
(7.2) to be performed.
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II apparatus.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The apparatus have isolating
transformers.
transformers.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such capacitors.
N
TRF No: IEC/EN 60065F
Click on the first or last page to see other HK 3480 (serv.man2) service manuals if exist.