HK 3390 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 46

Read Harman Kardon HK 3390 EMC - CB Certificate online

 
 
Page 40 of 43 -
 
 
 
 
 
 Report 
No. 
98502 
 
 
14 
TABLE: list of critical components and materials-continued 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference *) 
Sub transformer  
(T102)
 
 
Bobbin Mtl. 
alt. 
alt. 
 
Thermal fuse 
Seoul Electronics 
& Telecom Co 
 
EI DUPONT. 
WINTECH Poly. 
Samyang Co Ltd. 
 
Anzen Dangu Co.
 
KLT5J033YE / 
CLT5J033YE 
 
FR530  
CN9030 
2550GN30 
 
K11 
230V, Class E 
 
 
PET, V-0, 155°C
PET, V-0, 155°C
PET, V-0, 140°C
 
1A/250V, 115 
°C
IEC60065 
clause 14.3 
 
UL94 
UL94 
UL94 
 
IEC60691 
1.) 
 
 
UL, E69578 
UL, 
E2131445
 
UL, E121254 
 
VDE 
Socket-outlet 
(OL11) alt. 
Dae Ryung Elect. 
Dongbo Industri. 
A3-04-D007 
A304D007 
2.5A/250V ~ 
2.5A/250V ~ 
IEC60884-1 
IEC60884-1 
NEMKO  
NEMKO 
Mains fuse 
(F101) 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Elect. 
50T 
218 
004
 
5T 
TSD 
T4A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
Outlet fuse 
(F102) 
alt. 
alt. 
Littelfuse B.V. 
Bel Fuse. 
Save Fusetech. 
Wickmann-Werk. 
0663 
MRT 
SR-5 
TR5 382 
T2.5A 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
Sec. fuse 
(F603, F604) 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Elect. 
50T 
218 
06.3
 
5T 
TSD 
T6.3A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
Relay across 
the cap (C108) 
alt. 
alt. 
alt. 
Du San Industrial. 
Netron Tech. 
Sam Wha Cap. 
Murata Mfg. 
Jyh Chung Elect. 
NU 
AA 
SC 
KH 
JY 
0.0047uF/250V,
X1. 
IEC
60384-14,  
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
X-cap. (C109) 
alt. 
alt. 
alt. 
alt. 
Yuchang Elect. 
Pilkor Electronics. 
Pilkor Electronics. 
Okaya Electric  
Ultra Tech Xiphi. 
WBU1942 
PCX2 335M 
PCX2 335 
RE104 
HQX 
0.10uF, 275V 
X2 
IEC60384-14,  
2
nd
 ed. 
FIMKO 
FIMKO 
SEMKO 
FIMKO 
FIMKO 
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition 
Page of 57