Read Harman Kardon HK 3390 EMC - CB Certificate online
-
Page 36 of 43 -
Report
No.
98502
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23 - 26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT (K)
*), D113 (AC to +), S-c;
Input current stabilised at 1,19A.
F604 opened. No hazard (Tested time: 30 min).
Input current stabilised at 1,19A.
F604 opened. No hazard (Tested time: 30 min).
N/A N/A
*), D113 (AC to -), S-c;
Input current stabilised at 1,18A.
F603 opened. No hazard (Tested time: 20 min).
Input current stabilised at 1,18A.
F603 opened. No hazard (Tested time: 20 min).
N/A N/A
**), D113 (AC to -), S-c;
Input current stabilised at 1,09A.
F603 opened. No hazard (Tested time: 1 hr).
Input current stabilised at 1,09A.
F603 opened. No hazard (Tested time: 1 hr).
N/A N/A
*), C115, S-c;
Output signal off immediately. Input current stabilised at 0,13A.
F603 and F604 opened. No hazard (Tested time: 10 min).
Output signal off immediately. Input current stabilised at 0,13A.
F603 and F604 opened. No hazard (Tested time: 10 min).
N/A N/A
**), C115, S-c;
Output signal off immediately. Input current stabilised at 0,10A.
F603 and F604 opened. No hazard (Tested time: 10 min).
Output signal off immediately. Input current stabilised at 0,10A.
F603 and F604 opened. No hazard (Tested time: 10 min).
N/A N/A
*), C116, S-c;
Output signal off immediately. Input current stabilised at 0,13A.
F603 and F604 opened. No hazard (Tested time: 10 min).
Output signal off immediately. Input current stabilised at 0,13A.
F603 and F604 opened. No hazard (Tested time: 10 min).
N/A N/A
*), D114 (A to C), S-c;
Input current stabilised at 1,26A. R951 opened.
No hazard (Tested time: 1 hr 10 min).
Input current stabilised at 1,26A. R951 opened.
No hazard (Tested time: 1 hr 10 min).
N/A N/A
**), D114 (A to C), S-c;
Input current stabilised at 1,16A. R951 opened.
No hazard (Tested time: 30 min).
Input current stabilised at 1,16A. R951 opened.
No hazard (Tested time: 30 min).
N/A N/A
*), D117 (A to C), S-c;
Input current stabilised at 1,25A. R952 opened.
No hazard (Tested time: 30 min).
Input current stabilised at 1,25A. R952 opened.
No hazard (Tested time: 30 min).
N/A N/A
*), C121, S-c;
Output signal off immediately. Input current stabilised at 0,28A.
R951 and R952 damaged. No hazard (Tested time: 20 min).
Output signal off immediately. Input current stabilised at 0,28A.
R951 and R952 damaged. No hazard (Tested time: 20 min).
N/A N/A
*), C122, S-c;
Output signal off immediately. Input current stabilised at 0,28A.
R951 and R952 damaged. No hazard (Tested time: 40 min).
Output signal off immediately. Input current stabilised at 0,28A.
R951 and R952 damaged. No hazard (Tested time: 40 min).
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
Click on the first or last page to see other HK 3390 service manuals if exist.