HK 3390 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 43

Read Harman Kardon HK 3390 EMC - CB Certificate online

 
 
Page 37 of 43 -
 
 
 
 
 
 Report 
No. 
98502 
 
 
Monitored point: 
Under fault conditions specified below - continued 
dT (K) 
Limit dT (K)
***) 
*), Q319 (E to B), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A.  
F603 and F604 opened. Q319 and Q321damage.  
No hazard (Tested time: 10 min). 
N/A N/A 
*), Q319 (E to C), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A. 
F603 and F604 opened. Q321 damage. No hazard (Tested time: 10 min). 
N/A N/A 
*), Q321 (E to C), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A. 
F603 and F604 opened. Q319 damage. No hazard (Tested time: 10 min). 
N/A N/A 
*), Q321 (E to B), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A.  
F603 and F604 opened. Q319 and Q321damage.  
No hazard (Tested time: 10 min). 
N/A N/A 
*), Q315 (E to C), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A. 
No component damaged. No hazard (Tested time: 10 min). 
N/A N/A 
*), C307, S-c;  
SPK1 left output signal off immediately. Input current stabilised at 0,81A. 
R351 opened. No hazard (Tested time: 30 min). 
N/A N/A 
*), C309, S-c;  
SPK1 left output signal off immediately. Input current stabilised at 0,73A. 
R353 opened. No hazard (Tested time: 10 min). 
N/A N/A 
*), D110 (A to C), S-c;  
Sub transformer thermal fuse opened after 15 min.  
Dielectric strength test O.K. No hazard (Tested time: 15 min). 
Sub transf. 
117,2 
Sub transf.
150 
*), C112, S-c;  
Sub transformer thermal fuse opened after 13 min.  
Dielectric strength test O.K. No hazard (Tested time: 13 min). 
Sub transf. 
109,1 
Sub transf.
150 
*), Speaker output (SPK1 left- ch.), S-c;  
Unit shut down immediately. Input current stabilised at 0,009A.  
No component damaged. No hazard. (Tested time: 10 min). 
N/A N/A 
*) Tested voltage 253V               **) Tested voltage 198V 
***) Temperature rise limits for Singapore is 10K less 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded 
Page of 57