HK 3380 (serv.man10) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 37 - 
 
 
   
 Order 
No. 
14649
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D617 
S-c 
254,4 
A - C 
18 min 
1,16 A 
Sub transformer primary winding 
heated up to 114K and thermal fuse 
opened after 18 min. 
Dielectric strength test OK. 
No hazard. 
C625 
S-c 
254,4 
17 min 
0,05 A 
Unit shut down immediately. 
Sub transformer primary winding 
heated up to 116K and thermal fuse 
opened after 17 min. 
Dielectric strength test OK. 
No hazard. 
C626 
S-c 
254,4 
2 hr 
0,03 A 
Unit shut down immediately. 
Sub transformer primary winding 
heated up to 73K and stabilised. 
Dielectric strength test OK. 
No hazard. 
D607 
S-c 
254,4 
A - C 
1 hr 
F601 
1,44 A 
FL display off immediately. 
Input current stabilised at 1,15A. 
C619, C629, C632, D608, D609, 
Q602 damaged. 
No hazard. 
C632 
S-c 
254,4 
30 min 
F601 
1,30 A 
FL display off immediately. 
Input current stabilised at 1,10A. 
R616 opened. 
No hazard. 
SPK 1 
terminal 
S-c 
254,4 
L - G 
10 min 
F601, 
F603, 
F604 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
Cover 
opening 
Blocked 254,4  - 
18 
min. F601, 
F603, 
F604 
1,12 A 
The components are heated up to: 
- Main transf. pr. winding  : 35K 
- Sub transf. pr. winding  : 31K 
- D601 body 
 
: 56K 
- PWB near D601 
: 47K 
- Q319 body 
 
: 49K 
- PWB near Q319 
: 54K 
- IC65 heat-sink   
: 48K 
and protection circuit operated. 
Input current stabilised at 0,01A. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 49
Display