Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 31 of 37 -
Order
No.
14649
A
ANNEX A, ADDITIONAL
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
Not intended for outdoor use.
N
A.5.1
j) Marked with IPX4 (IEC 60 529),
5.4.1 a) does not apply
5.4.1 a) does not apply
N
A.10.2.1
Enclosure provides protection
against splashing water
against splashing water
N
A.10.2.2
Humidity treatment carried out for
7 days
7 days
N
B
ANNEX B, APPARATUS TO BE
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
Not intended for telecommunication networks
N
B.5.4.1
e) Where the separation of TNV
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
N
B.8.1
TNV circuits separated from the
mains circuit and from hazardous
live parts by either:
mains circuit and from hazardous
live parts by either:
N
a) double or reinforced insulation
N
b) basic insulation with earthed
protective screening
protective screening
N
B.8.2
TNV circuits separated from circuits
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
N
B.9.1.1
TNV circuit terminals contacts which
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
N
B.10.1
Insulation between TNV terminals
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
N
B.14.12
Surge suppressors between TNV
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
N
Click on the first or last page to see other HK 3380 (serv.man10) service manuals if exist.