Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 37 -
Order
No.
14649
FAULT CONDITION TESTS
P
Ambient temperature
25,0 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D602
S-c
207
A - C
30 min.
F601
1,07 A
Normal operating.
Input current stabilised at 1,06A.
R605 damaged.
No hazard.
Input current stabilised at 1,06A.
R605 damaged.
No hazard.
D602
S-c
254,4
A - C
30 min.
F601
1,15 A
Normal operating.
Input current stabilised at 1,12A.
R605 damaged.
No hazard.
Input current stabilised at 1,12A.
R605 damaged.
No hazard.
D605
S-c
254,4
A - C
30 min.
F601
1,14 A
Normal operating.
Input current stabilised at 1,12A.
R606 damaged.
No hazard.
Input current stabilised at 1,12A.
R606 damaged.
No hazard.
C611
S-c
207
-
10 min.
F601
0,60 A
Output signal off immediately.
Input current stabilised at 0,18A.
R605, R606 opened.
No hazard.
Input current stabilised at 0,18A.
R605, R606 opened.
No hazard.
C611
S-c
254,4
-
10 min.
F601
0,70 A
Output signal off immediately.
Input current stabilised at 0,24A.
R605, R606 opened.
No hazard.
Input current stabilised at 0,24A.
R605, R606 opened.
No hazard.
C613
S-c
254,4
-
50 min.
F601
0,42 A
Output signal off immediately.
Input current stabilised at 0,26A.
No component damaged.
No hazard.
Input current stabilised at 0,26A.
No component damaged.
No hazard.
D601
S-c
207
AC - +
30 min.
F601,
F603,
F604
F603,
F604
6,10 A
Normal operating.
Input current stabilised at 1,00A.
F604 opened.
No hazard.
Input current stabilised at 1,00A.
F604 opened.
No hazard.
D601
S-c
254,4
AC - +
30 min.
F601,
F603,
F604
F603,
F604
10,1 A
Normal operating.
Input current stabilised at 1,06A.
F604 opened.
No hazard.
Input current stabilised at 1,06A.
F604 opened.
No hazard.
D601
S-c
207
AC - -
30 min.
F601,
F603,
F604
F603,
F604
5,40 A
Normal operating.
Input current stabilised at 0,99A.
F603 opened.
No hazard.
Input current stabilised at 0,99A.
F603 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other HK 3380 (serv.man10) service manuals if exist.