HK 3380 (serv.man10) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 39

Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 37 - 
 
 
   
 Order 
No. 
14649
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
25,0 °C 
Rated voltage   
230V~ 50Hz 
Remarks  
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D602 
S-c 
207 
A - C 
30 min. 
F601 
1,07 A 
Normal operating. 
Input current stabilised at 1,06A. 
R605 damaged. 
No hazard. 
D602 
S-c 
254,4 
A - C 
30 min. 
F601 
1,15 A 
Normal operating. 
Input current stabilised at 1,12A. 
R605 damaged. 
No hazard. 
D605 
S-c 
254,4 
A - C 
30 min. 
F601 
1,14 A 
Normal operating. 
Input current stabilised at 1,12A. 
R606 damaged. 
No hazard. 
C611 
S-c 
207 
10 min. 
F601 
0,60 A 
Output signal off immediately. 
Input current stabilised at 0,18A. 
R605, R606 opened. 
No hazard. 
C611 
S-c 
254,4 
10 min. 
F601 
0,70 A 
Output signal off immediately. 
Input current stabilised at 0,24A. 
R605, R606 opened. 
No hazard. 
C613 
S-c 
254,4 
50 min. 
F601 
0,42 A 
Output signal off immediately. 
Input current stabilised at 0,26A. 
No component damaged. 
No hazard. 
D601 
S-c 
207 
AC - + 
30 min. 
F601, 
F603, 
F604 
6,10 A 
Normal operating. 
Input current stabilised at 1,00A. 
F604 opened. 
No hazard. 
D601 
S-c 
254,4 
AC - + 
30 min. 
F601, 
F603, 
F604 
10,1 A 
Normal operating. 
Input current stabilised at 1,06A. 
F604 opened. 
No hazard. 
D601 
S-c 
207 
AC - - 
30 min. 
F601, 
F603, 
F604 
5,40 A 
Normal operating. 
Input current stabilised at 0,99A. 
F603 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 