Read Harman Kardon HK 3380 (serv.man10) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 13 of 37 -
Order
No.
14649
8.11
Detaching of wires
P
No undue reduction of creepage or
clearance distances if wires become
detached
clearance distances if wires become
detached
Primary wires connected with multi-contact-housing
.
P
Vibration test carried out
Vibration test considered not necessary
N
8.12
Adequate cross-sectional area of
internal wiring to mains socket-
outlets
internal wiring to mains socket-
outlets
No internal wiring for mains socket-outlets
N
8.13
Adequate fastening of windows,
lenses, lamp covers etc. (push or
pull test 20 N for 10 s)
lenses, lamp covers etc. (push or
pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push
or pull test 50 N, for 10 s)
or pull test 50 N, for 10 s)
Covers adequately fastened with screws.
P
8.15
No risk of damage to the insulation
of internal wiring due to hot parts or
sharp edges
of internal wiring due to hot parts or
sharp edges
Wires safely anchored away from parts with high
temperature.
temperature.
P
8.16
Apparatus designed to be supplied
by special supply apparatus only.
by special supply apparatus only.
N
9
ELECTRIC SHOCK HAZARD
UNDER NORMAL OPERATING
CONDITIONS
UNDER NORMAL OPERATING
CONDITIONS
P
9.1.1
Touch current expressed as voltages
U1 and U2 in Annex D
U1 and U2 in Annex D
P
Location Measured
U1
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
Pole 1 - RCA terminal
0,24 V peak
-
0,03 V peak
Pass
Pole 2 - RCA terminal
0,23 V peak
-
0,02 V peak
Pass
Discharge not exceeding 45
µ
C
No part or contact of a terminal with stored voltages
between 60V - 15kV
between 60V - 15kV
N
Energy of discharge not exceeding
350 mJ
350 mJ
No part or contact of a terminal with stored voltages
exceeding 15kV
exceeding 15kV
N
Test with test finger according to test
probe B of IEC 61 032 (20N)
probe B of IEC 61 032 (20N)
No access to hazardous live parts
P
For class II constructions, test with
test probe 13 of IEC 61 032 (3N)
test probe 13 of IEC 61 032 (3N)
No access to hazardous live parts
P
Clearances to circuits exceeding
1000V a.c. or 1500V d.c.
1000V a.c. or 1500V d.c.
No voltages exceeding 1000V AC or 1500V DC.
N