IEC 60065, 6th edition : 1998
 - 
- Page 9 of 37 - 
 
 
   
 Order 
No. 
14649
 
 
 
 
HEATING  
 
t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
22,5 °C 
22,5 °C
 
 
t2 =   
23,1 °C 
25,1 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
 R2/
 
t measured 
t allowed *) 
Insulation 
class 
  Main transf. pr. winding (207V) 
5,13 
6,34 
60,0 
85 
Class E 
  Sub transf. pr. winding (207V) 
2789 
3162 
33,8 
85 
Class E 
 
 
 
 
 
 
  Main transf. pr. winding (254,4V) 
5,13 
6,62 
72,0 
85 
Class E 
  Sub transf. pr. winding (254,4V) 
2789 
3338 
48,0 
85 
Class E 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Main transformer core 
46,5 
55,0 
85 
Sub transformer core 
27,8 
37,5 
85 
Diode, D601 body 
45,7 
48,7 
PWB near D601 
34,6 
37,5 
85 
PWB near CN63 
31,9 
36,7 
85 
Regulator, IC65 heat-sink 
28,5 
42,6 
TR, Q319 body 
39,3 
49,8 
PWB near Q319 
29,3 
37,9 
85 
E. Capacitor, C601 body 
19,8 
23,2 
Main 
heat-sink 
41,9 52,7 - 
Power cord bushing 
12,4 
15,0 
60 
Top enclosure above main heat-sink 
22,6 
26,4 
40 
Top enclosure above main transformer 
19,8 
23,5 
40 
Switch 
button 
0,5 0,5 50 
 
 
 
 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
Test wall condition: 50 cm at top, 10 cm at other side 
 
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
 
 
 