Page 7 of 55
Report No. JSH0503351-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065F
TRF originator BEAB
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Inside the transformer, at least
3 layers of polyester film
between the primary wiring and
secondary wiring.
3 layers of polyester film
between the primary wiring and
secondary wiring.
Pass
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N/A
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N/A
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Internal primary wiring
Pass
8.11
Detaching of wires
N/A
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached.
detached.
N/A
Vibration test carried out ................................... : No
N/A
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlet.
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Pass
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Fastened by metal screws.
Pass
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Internal wires are routed away
from sharp and hot things, and
firmly secured.
from sharp and hot things, and
firmly secured.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such winding used.
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
Type: the mains plug.
Pass
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
N/A