HD 970 (serv.man7) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 7

Read Harman Kardon HD 970 (serv.man7) EMC - CB Certificate online

 
 
Page 6 of 55 
Report No. JSH0503351-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark  
Verdict 
 
TRF No:  IECEN60065F 
TRF originator BEAB 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Class II equipment. 
N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
 
Pass 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 
Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Class II type main transformer 
used. 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such capacitor.  
N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitor.  
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Y1 capacitor C2 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 
N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
 
N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 
N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part  
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) 
........................................................................ : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  ................. :  Transformer bobbin: 1.4mm.  
The insulation sheet below the 
power supply board: 0.4mm. 
Pass 
 
Thin sheet insulation 
 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
Page of 61