GO AND PLAY (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 109

Read Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate online

 
 
<12007721 001> 
 
 
Page 99 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Australian National Differences  
 
If possible, the flame shall be applied at least 
10 mm from a corner. 
8.5 Replacement: 
The test shall be made on one specimen. If the 
specimen does not withstand the test, the test 
may be repeated on two further specimens, both 
of which shall then withstand the test. 
 
10 Evaluation of test results 
Replace with: 
The duration of burning (t
b
) shall not exceed 30 s. 
However, for printed circuit boards, it shall not 
exceed 15 s. 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
according to IEC 60695-11-10, provided that the 
sample tested was not thicker than the relevant 
part.  
YY.1.3 
If parts, other than enclosures, do not withstand 
to glow-wire tests of YY.1.2, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
YY.1.2 is made on all parts of non-metallic 
material which are within a distance of 50 mm or 
which are likely to be impinged upon by flame 
during the tests of YY.1.2. Parts shielded by a 
separate barrier which meets the needle-flame 
test are not tested. 
NOTE 1 - If the enclosure does not withstand the 
glow-wire test the equipment is considered to 
have failed to meet the requirement of Annex YY 
without the need for consequential testing. 
NOTE 2 - If other parts do not withstand the 
glow-wire test due to ignition of the tissue paper 
and if this indicates that burring or glowing 
particles can fall onto an external surface 
underneath the equipment, the equipment is 
considered to have failed to meet the 
requirement of Annex YY without the need for 
consequential testing. 
NOTE 3 - Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame, positioned above the point of the material 
supporting in contact with or in close proximity to 
connections. 
 
YY.2 
The base material of printed boards is subjected 
to needle-flame test to Clause YY.1.2. The flame 
 
Page of 115