Read Harman Kardon GLA 55 (serv.man3) EMC - CB Certificate online
- Page 10 of 52 -
www.nemko.com
Report No. 115972
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.8.1 Identification,
location and marking ................... :
No control.
N/A
1.7.8.2 Colours .............................................................. :
For functional indication a LED
lights when the equipment is
operating.
lights when the equipment is
operating.
N/A
1.7.8.3 Symbols
............................................................ :
There is no switch in the
equipment, functional control is
marked with “+” and “-” for
volume control.
equipment, functional control is
marked with “+” and “-” for
volume control.
N/A
1.7.8.4 Markings
using figures ..................................... :
N/A
1.7.9
Isolation of multiple power sources ................... :
Class III equipment.
N/A
1.7.10
IT power distribution systems
Class III equipment.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12
Language ........................................................... :
Instructions and markings shall
be in a language acceptable for
the country where the
equipment is to be used.
be in a language acceptable for
the country where the
equipment is to be used.
—
1.7.13 Durability
The marking withstands
required tests.
required tests.
P
1.7.14 Removable
parts
No removable parts.
N/A
1.7.15 Replaceable
batteries
No battery in the equipment.
N/A
Language............................................................ :
—
1.7.16 Operator
access with a tool................................ :
All areas containing hazard(s)
are inaccessible to the
operator.
are inaccessible to the
operator.
N/A
1.7.17
Equipment for restricted access locations.......... :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2
PROTECTION FROM HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment.
N/A
Test by inspection .............................................. :
N/A
Test with test finger ........................................... :
N/A
Test
with
test pin ................................................ :
N/A
Test
with
test probe ........................................... :
N/A
2.1.1.2 Battery
compartments ....................................... :
No TNV circuits in the
equipment.
equipment.
N/A
Click on the first or last page to see other GLA 55 (serv.man3) service manuals if exist.