GLA 55 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon GLA 55 (serv.man3) EMC - CB Certificate online

 
 
- Page 8 of 52 - 
 
 
www.nemko.com
 
Report No.  115972 
 
TRF No.:IECEN60950_1B 
 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
1 GENERAL 
 
 
1.5 Components 
 
1.5.1 General 
 
 
 
Comply with IEC 60950 or relevant component 
standard  
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
Certified components are used 
in accordance with their ratings, 
certifications and they comply 
with applicable parts of this 
standard. 
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950-1 
and the relevant component 
standard. 
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950-1. 
1.5.3 Thermal 
controls 
No thermal controls. 
N/A 
1.5.4 Transformers 
Class III equipment to be 
supplied by a separately 
approved power supply with an 
SELV output. Power supply is 
evaluated. Refer to Summary of 
Testing. 
N/A 
1.5.5 Interconnecting 
cables 
No interconnecting cables. 
1.5.6 
Capacitors in primary circuits ............................ :
Class III equipment. 
N/A 
1.5.7 
Double insulation or reinforced insulation bridged 
by components 
Class III equipment. 
N/A 
1.5.7.1 General 
Refer below: 
 
1.5.7.2 Bridging 
capacitors 
Class III equipment. 
N/A 
1.5.7.3 Bridging 
resistors 
Class III equipment. 
N/A 
1.5.7.4 Accessible 
parts 
Class III equipment. 
N/A 
1.5.8 
Components in equipment for IT power systems 
Class III equipment. 
N/A 
 
Page of 90
Display