Read Harman Kardon GLA 55 (serv.man3) EMC - CB Certificate online
- Page 9 of 52 -
www.nemko.com
Report No. 115972
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.6 Power
interface
—
1.6.1
AC power distribution systems
DC supplied.
N/A
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Markings and instructions
—
1.7.1
Power rating
The required marking is located
on the outside surface of the
equipment.
on the outside surface of the
equipment.
P
Rated voltage(s) or voltage range(s) (V) ........... :
18Vdc
—
Symbol for nature of supply, for d.c. only ........... :
IEC 60417, symbol No. 5031, is
used.
used.
P
Rated frequency or rated frequency range (Hz) :
DC supplied.
—
Rated
current
(mA or A) .................................... :
3.33A
—
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
harman/kardon
—
Type/model or type reference ............................ :
GLA-55
—
Symbol
of for Class II equipment only ............... :
Class III equipment.
N/A
Other
symbols ................................................... :
The additional marking does
not give rise to
misunderstandings.
not give rise to
misunderstandings.
N/A
Certification marks ............................................. :
Refer to copy of markings.
—
1.7.2 Safety
instructions
Provided with marking
regarding use of specified
power supply, refer to marking
label.
regarding use of specified
power supply, refer to marking
label.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4 Supply
voltage adjustment ................................ :
No voltage selector.
N/A
1.7.5 Power
outlets
on the equipment ........................ :
No standard power outlet.
N/A
1.7.6 Fuse
identification .............................................. :
No fuse.
N/A
1.7.7 Wiring
terminals
Refer below:
—
1.7.7.1
Protective earthing and bonding terminals ........ :
Class III equipment.
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
Class III equipment.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
Class III equipment.
N/A
1.7.8
Controls and indicators
Refer below:
—