Page 76 of 84                        Report No. EFSN13070410E-1 
 
TRF No. IEC60950_1C 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
3.3.5 
Revise first column of Table 3E to “Smaller of the 
RATED CURRENT of the equipment or the 
PROTECTIVE CURRENT RATING of the circuit under 
consideration.” 
 
N/A 
3.4.2 
Motor control devices are provided for cord-connected 
equipment with a motor if the equipment is rated more 
than 12 A 
 
N/A 
 
- or if the motor has a nominal voltage rating greater 
than 120 V 
 
N/A 
 
- or is rated more than 1/3 hp (locked rotor current over 
43 A) 
 
N/A 
3.4.8 
Vertically-mounted disconnect switches and circuit 
breakers have the "on" position indicated by the handle 
in the up position. 
 
N/A 
3.4.11 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for five 
minutes have a battery disconnect means that may be 
connected to the computer room remote power-off 
circuit. 
 
N/A 
4.3.12 
The maximum quantity of flammable liquid stored in 
equipment complies with NFPA 30. 
 
N/A 
4.3.13.5 
Equipment with lasers meet the Canadian Radiation 
Emitting Devices Act, REDR C1370 and/or Code of 
Federal Regulations 21 CFR 1040, as applicable. 
 
N/A 
4.7 
For computer room applications, automated 
information storage systems with combustible media 
greater than 0.76 m
3
 (27 cu ft) have a provision for 
connection of either automatic sprinklers or a gaseous 
agent extinguishing system with an extended 
discharge. 
 
N/A 
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 m
2
 
(10 sq ft) or a single dimension greater than 1.8 m (6 
ft) have a flame spread rating of 50 or less. 
 
N/A 
 
For other applications, enclosures with the same 
dimensions require a flame spread rating of 200 or 
less. 
 
N/A 
Annex H 
Equipment that produces ionizing radiation comply with 
the Canadian Radiation Emitting Devices Act, REDR 
C1370 and/or Code of Federal Regulations, 21 CFR 
1020, as applicable. 
 
N/A 
 
Other National Differences 
-- 
1.5.1 
Some components and materials associated with the 
risk of fire, electric shock, or personal injury have 
component or material ratings in accordance with the 
applicable national (Canadian and/or U.S.) component 
or material standard requirements. 
 
1.6.1.2 
A circuit for connection to the DC Mains Supply is 
classified as either a SELV Circuit, TNV-2 Circuit or 
Hazardous Voltage Circuit depending on the maximum 
operating voltage of the supply 
 
N/A 
 
This maximum operating voltage includes 
consideration of the battery charging “float voltage” 
associated with the intended supply system, 
regardless of the marked power rating of the 
equipment. 
 
N/A 