Page 74 of 84                        Report No. EFSN13070410E-1 
 
TRF No. IEC60950_1C 
 
 
 
ATTACHMENT TO TEST REPORT IEC 60950-1  
UNITED STATES NATIONAL DIFFERENCES  
Information technology equipment 
– Safety – 
Part 1: General requirements 
Differences according to .............. : UL 60950-1-07 
Attachment Form No..................... : US_ND_IEC60950_1C 
Attachment Originator .................. : TÜV SÜD Product Service GmbH 
Master Attachment ........................ : Date (2012-08) 
Copyright © 2012 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), 
Geneva, Switzerland. All rights reserved. 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
1.1.1 
All equipment is to be designed to allow installation in 
accordance with the National Electrical Code (NEC), 
ANSI/NFPA 70, the Canadian Electrical Code (CEC), 
Part I, CAN/CSA C22.1, and when applicable, the 
National Electrical Safety Code, IEEE C2. 
 
 
Also, unless marked or otherwise identified, installation 
is allowed per the Standard for the Protection of 
Electronic Computer/Data-Processing Equipment, 
ANSI/NFPA 75. 
 
N/A 
1.4.14 
For Pluggable Equipment Type A, the protection in the 
installation is assumed to be 20 A. 
 
N/A 
1.5.5 
For lengths exceeding 3.05 m, external interconnecting 
flexible cord and cable assemblies are required to be a 
suitable cable type (e.g., DP, CL2) specified in the 
CEC/NEC. 
 
N/A 
1.5.5 
For lengths 3.05 m or less, external interconnecting 
flexible cord and cable assemblies that are not types 
specified in the CEC are required to have special 
construction features and identification markings. 
 
 
External cable assemblies that exceed 3.05 m in 
length to be types specified in the NEC and CEC  
 
N/A 
1.7.1 
Equipment for use on a.c. mains supply systems with a 
neutral and more than one phase conductor (e.g. 
120/240 V, 3-wire) require a special marking format for 
electrical ratings. 
 
N/A 
 
A voltage rating that exceeds an attachment plug cap 
rating is only permitted if it does not exceed the 
extreme operating conditions in Table 2 of CAN/CSA 
C22.2 No. 235, and 
 
N/A 
 
- if it is part of a range that extends into the Table 2 
"Normal Operating Conditions." 
 
N/A 
 
A voltage rating is not be lower than the specified 
"Normal Operating Conditions," unless it is part of a 
range that extends into the "Normal Operating 
Conditions." 
 
N/A 
1.7.7 
Wiring terminals intended to supply Class 2 outputs in 
accordance with CEC Part 1 or NEC are marked with 
the voltage rating and “Class 2” or equivalent. 
 
N/A 
Page of 85