 Report 
No. 
98390 
 
 
 
8.19 
Disconnection from the mains 
See below
 
8.19.1 Disconnect 
device 
Appliance coupler is used  
as disconnect devices. 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
No mains switch 
N/A 
8.19.2 
Mains switch ON indication 
“ON” indication by lamp or 
FL display for secondary 
functional switch.
 
N/A 
8.20 
Switch not fitted in the mains cord 
No mains cord used.
 
N/A 
8.21 
Bridging components comply with clause 14 
No bridging components  
for switch
 
N/A 
8.22 
Non-separable thin sheet material 
No non-separable thin  
sheet material. 
N/A 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding 
1000V AC or 1500V DC.
 
N/A 
9.1.1.1 
a) Open circuit voltages 
Mains input voltage > 35V,  
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ............................. : 
See attachment, Table to E
N/IEC 60065 7
th
 edition. 
 
 
c) Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored voltages 
between 60V - 15 kV.
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ 
No part or contact of  
a terminal with stored  
voltages exceeding 15kV
 
N/A 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous  
live parts
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No live shaft, handles or 
levers
 
N/A 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
No ventilation holes in top  
side of the cover.
 
N/A 
Page of 61