Read Harman Kardon DVD 39 (serv.man2) EMC - CB Certificate online
- Page 12 of 42 -
Report
No.
98390
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Insulation in TF91 and
TF92 transf. between pri.
and sec. windings.
TF92 transf. between pri.
and sec. windings.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated.
P
Adequate insulation between internal hazardous
live parts and conductors connected to
accessible parts
live parts and conductors connected to
accessible parts
Single insulation but
safely anchored.
safely anchored.
P
8.10
Double insulation between conductors connected
to the mains and accessible parts.
to the mains and accessible parts.
Double insulation between internal hazardous
live parts and conductors connected to accessible
parts.
live parts and conductors connected to accessible
parts.
Double insulated,
tested according to 8.9
and 10.3.
tested according to 8.9
and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Inlet connected wires
hooked-in before soldered.
Other end of the inlet wires
are connected with
multi-contact housing.
hooked-in before soldered.
Other end of the inlet wires
are connected with
multi-contact housing.
P
Vibration
test
carried out ..................................... :
See 12,1,2
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temperature.
away from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such winding wire.
N/A
8.18
Endurance test as required by 8.17
N/A
Click on the first or last page to see other DVD 39 (serv.man2) service manuals if exist.