No. 
89538 
 
 
 
 
14.3.3 
Transformer/motor, constructional requirements 
Transformer 
Part No. 
Insulation 
between 
Insulation Res.
M Ohms 
Test Volt 
  V (60 sec.) 
Clearances / Creepage distance
Measured 
Required 
T901
/ CLT9Z021ZE, 
or
      CLT9Z018ZE 
Pri. - Sec.  > 100 
3KV (rms) 
6,0 / 6,0 mm 
4,4 / 5,6 mm 
 
 
 
 
 
 
- Min. 3,0 mm barrier tape or spacing provided in primary side of the transformer. 
- Min. 6,0 mm barrier tape or spacing provided in secondary side of the transformer. 
All of exposed primary winding wires, and outer pins (7, 15) connected exposed secondary winding  
wires are covered fully by the 0,25mm min. thick. Teflon tubing (PTFE). 
Components / construction 
(T901)
 
Concentric windings on one bobbin. At least 3 layers of  
insulation between primary and secondary winding.  
Thickness of each layer: 0.025 mm.  Test voltage: 3kV 
 
Max. Working voltage:
  540Vpeak / 271Vrms 
Transformer 
Part No 
Insulation 
Between 
Thick (mm) 
X Number 
Material 
Dielectric strength test 
60 sec. 
T901
/ CLT9Z021ZE, 
or
      CLT9Z018ZE 
Pr. - Sec. 
0,025 mm x 3 
Polyester  tape 
2 layers tested - Pass *) 
 
Pr. - ic 
0,50 mm min. x 1
Phenolic bobbin 
1 layer tested - Pass *) 
 
Pr. / Sec. 
0,25 mm min. x 1
Teflon tube (PTFE) 
1 layer tested - Pass *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms. 
 
17.1 
Torque test to Table 20: 
Screw 
Diameter 
With 
Without
Material 
Torque test (Nm) 
Location / function 
(mm) 
Head 
Head 
Screw
Nut 
Fulfilled / Remarks 
Fixing of top cover 
 
Metal 
Metal 
0,5Nm, 5 times / Pass 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 61