Read Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate online
- Page 4 of 6 -
Report
No.
89538
11
FAULT CONDITON TESTS –continued
P
Comp.
No.
No.
Location
Fault
Test V Test
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
IC91
Pin (1-4) S-c
253
10 min
F901
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
PC91
Pin (3-4) S-c
253
10 min
F901
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded