 Report 
No. 
89538 
 
 
 
 
11 
FAULT CONDITIONS TESTS
 
 
Voltage(V) 0,9 or 1,1 times rated voltage……….
198V or 253V 
— 
 
Ambient temperature(℃)…………………………
23 - 26
°C 
— 
Comp. 
No. 
Location 
Fault  
Test V  Test 
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D924 
A - C 
S-c 
253 
20 min 
F901 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C928 
S-c 
253 
10 min 
F901 
0,15 A 
DVD player stop immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
D923 
A - C 
S-c 
253 
20 min 
F901 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
C927 
S-c 
253 
15 min 
F901 
0,02 A 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
D922 
A - C 
S-c 
253 
10 min 
F901 
0,07 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
C925 
S-c 
253 
20 min 
F901 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
D921 
A - C 
S-c 
253 
50 min 
F901 
0,08 A 
DVD player stopped immediately.
Input current stabilised at 0,08A. 
T901 coil heated up to 40,8K and
stabilised. 
No component damaged. 
No hazard. 
C923 
S-c 
253 
10 min 
F901 
0,03 A 
Unit shut down immediately. 
Input current stabilised at 0,03A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
 