Test report no. JSH0311046-001 
                                          
                Page 13 of 19 
 
 
8.4 Measurement uncertainty 
 
Disturbance power, quasi-peak detection:          + 3.92 dB 
Disturbance power, average detection:               + 3.92 dB 
 
The measurement uncertainty described the overall uncertainty of the given measured value during 
operation of the EUT in the above mentioned way. 
Measurement uncertainty is calculated in accordance with WECC 19-1990. 
The measurement uncertainty is given with a confidence of 95% 
 
8.5 Test instrumentation 
 
 
Equipment                                                 Manu.                               Type                      
 
Test receiver 
 
 
         R & S 
 
      ESCS 30 
Field Strength Detector 
 
         USA 
 
      FP4000 
 
Receive Attenna   
 
         SCHAFFNER 
      CBL6112B 
Antenna mask    
 
         
 
 
       MA240 
 
 
 turn table 
 
      
 
 
 
       DS420S 
 
 
 
8.6 Test protocol  
 
FM Mode 
Frequency 
(MHz) 
Emission level 
(dBuV) 
Limits 
(dBuV) 
Margin 
(dBuV) 
Polarisation 
100   40.0  H&V 
144   40.0  H&V 
200   40.0  H&V 
300   47.0  H&V 
500   47.0  H&V 
Local oscillator  
(Fundamental) 
 
 
60 
 H&V 
(Harmonic 80-
300) 
 
 
52 
 H&V 
(Harmonic 300-
1000) 
 
 
56 
 H&V 
1000  47  
H&V 
 
Note: * means the emission level 6dB lower than limit. 
 