10.5 Test protocol
The tested object operated under the operating condition specified in EN 61000-3-3:1995.The
following limits apply according to EN 61000-3-3:1995.
--the relative steady-state voltage change ,dc, shall not exceed 3%;
--the maximum relative voltage change, dmax, shall not exceed 4%
--the value of d(t) during a voltage change shall not exceed 3% for more than 200ms;
-- for voltage changes caused by manual switching or occur less frequently than once per hour, The Pst
and Plt requirements shall not be applicable. three requirements related to voltages shall be applicable
with the previously mentioned voltage values, multiplied by a factor of 1.33.
The following tables (Table ) are those measured by an automatic measuring system.
dc
dmax d(t) Pst
Plt
Limits 3.00%/3.99%*
4.00%/5.32%*
3%/3.99*
200ms 1.000 0.650
Measured
* For voltage changes caused by manual switching the voltage values multiplied by a factor of
1.33