Read Harman Kardon DVD 21 (serv.man14) EMC - CB Certificate online
page 10 of 31
Ref.No.:JSH02*1896-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2:nd Edition : Y1: C3, C4, C5, C7
P
14.2.2
X capacitors tested to IEC 60384-14, 2:nd Edition : X2: C1, C2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N
14.2.5
Capacitors with volume exceeding 1750 mm
3
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ....................................................................... :
compliance with IEC 60384-1, 4.38 category B or
better ....................................................................... :
C6 metal case
N
Capacitors with volume exceeding 1750 mm
3
,
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ........................................ :
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ........................................ :
N
Shielded by a barrier to FV 0 or metal ................... :
N
14.3
Inductors and windings
14.3.1
Transformers and inductors marked with
manufacturer’s name and type .............................. :
manufacturer’s name and type .............................. :
BCK-ER2803 P
Transformers and inductors separately approved : No, tested with appliance
N
14.3.2
Isolating transformer complies with 14.3.3,
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3, 14.3.4.1 and 14.3.5.1
P
Separating transformer complies with 14.3.3,
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
N
Flammability test of insulating material acc. to
20.1.4 (except in thin sheet form)
20.1.4 (except in thin sheet form)
P
14.3.3.1
Clearances and creepage distances according to
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
P
Coil formers and partition walls
≥ 0.4 mm
0.8mm minimum
P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N
4.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
P
Coil formers and partition walls
≥ 0.4 mm
P